EEE 413: Electrical Building Services Design & Installation Drafting

Load estimation, lumen method illumination design, cable sizing (BS 7671 / IEC 60364), conduit routing, distribution board schedules, and lightning protection.

Instructor
Created by PAMCET Learning Team
advanced2 - 4 weeksEnglish

Course Overview

Load estimation, lumen method illumination design, cable sizing (BS 7671 / IEC 60364), conduit routing, distribution board schedules, and lightning protection. Curriculum Structure & Core Modules: • 1. Introduction to Building Electrical Services, Regulations, and Codes (IEC...

What You'll Learn

  • Perform interior lighting calculations using the Lumen method and evaluate illuminance levels according to CIE/CIBSE standards.
  • Estimate connected and maximum diversified electrical loads for residential, commercial, and industrial facilities.
  • Size electrical power cables based on current carrying capacity, voltage drop limits, and thermal correction factors (BS 7671).
  • Design single-line diagrams, distribution board schedules, and lightning protection systems compliant with IEC 62305.

Requirements

  • Pass in EEE 107 and EEE 204.

Degree Programme Curriculum Context

This course is a curriculum unit of the Bachelor of Engineering (B.Eng.) in Electrical & Electronic Engineering degree framework in Nigeria.

Earn Your Certificate

Showcase your skills with a certificate! Complete the course, submit your project, and earn your certificate. Here's a sample of what you'll receive to show off your accomplishments.

course-certificate
Lecture Board & Syllabus

Course Curriculum

Browse complete theoretical foundations, worked calculations, laboratory protocols, and board assessment questions under each topic.

Launch Course Reader →
8 Chapters
•
16 Lecture
•
24h
Subtopic 1Document LectureOpen Access~22 min read

Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code): Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 1 • Lecture 1 Chapter 1: Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code) — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE41...

Module 1 • Subtopic 1•18,134 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code): Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 1 • Lecture 2 Chapter 1: Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code) — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Qual...

Module 1 • Subtopic 2•24,898 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 1 Formative Assessment: Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code)

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 1: Introduction to Building Electrical Services, Regulations, and Codes (IEC 60364, BS 7671, Nigerian National Building Code).

Module 1 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 2 • Lecture 1 Chapter 2: Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 • COREN-EE-D...

Module 2 • Subtopic 1•17,958 characters of authentic academic content
Subtopic 2Document LectureOpen Access~31 min read

Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 2 • Lecture 2 Chapter 2: Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management...

Module 2 • Subtopic 2•25,732 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 2 Formative Assessment: Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 2: Lighting Design: Photometric Concepts, Luminous Flux, Illuminance Levels, and Lumen Method Calculations.

Module 2 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 3 • Lecture 1 Chapter 3: Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 • COREN-E...

Module 3 • Subtopic 1•18,054 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 3 • Lecture 2 Chapter 3: Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Managem...

Module 3 • Subtopic 2•24,850 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 3 Formative Assessment: Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 3: Electrical Load Assessment: Connected Load, Demand Factor, Diversity Factor, and Maximum Demand Estimation.

Module 3 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 4 • Lecture 1 Chapter 4: Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 &b...

Module 4 • Subtopic 1•18,017 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 4 • Lecture 2 Chapter 4: Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality...

Module 4 • Subtopic 2•27,484 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 4 Formative Assessment: Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 4: Cable Sizing Methodology: Current-Carrying Capacity, Grouping Derating, Ambient Temperature Derating, and Voltage Drop.

Module 4 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 5 • Lecture 1 Chapter 5: Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 • COREN-EE-DES-0...

Module 5 • Subtopic 1•18,031 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 5 • Lecture 2 Chapter 5: Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1....

Module 5 • Subtopic 2•24,841 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 5 Formative Assessment: Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 5: Protective Devices: Miniature Circuit Breakers (MCB), Molded Case Circuit Breakers (MCCB), and RCDs.

Module 5 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 6 • Lecture 1 Chapter 6: Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 • COREN-EE-DES-03 • IEEE...

Module 6 • Subtopic 1•17,916 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 6 • Lecture 2 Chapter 6: Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1. Applied Engin...

Module 6 • Subtopic 2•24,752 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 6 Formative Assessment: Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 6: Distribution Boards, Final Sub-Circuits, Conduit Sizing, and Cable Tray Route Planning.

Module 6 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 7 • Lecture 1 Chapter 7: Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE411 • COREN-EE-...

Module 7 • Subtopic 1•18,339 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 7 • Lecture 2 Chapter 7: Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Managemen...

Module 7 • Subtopic 2•27,454 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 7 Formative Assessment: Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 7: Earthing Systems: TN-S, TN-C-S, TT Configurations, Earth Electrode Resistance, and Equipotential Bonding.

Module 7 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection: Theoretical Foundations, Modeling & System Architecture

EEE 413 • 400L • Electrical Engineering Chapter 8 • Lecture 1 Chapter 8: Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Electrical Building Services Design & Installation Drafting • NUC-CCMAS-ENG-EEE...

Module 8 • Subtopic 1•18,299 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection: Applied Engineering Computation, Production & Verification

EEE 413 • 400L • Electrical Engineering Chapter 8 • Lecture 2 Chapter 8: Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Qu...

Module 8 • Subtopic 2•27,967 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 413 Ch 8 Formative Assessment: Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 8: Structural Lightning Protection Design (IEC 62305): Risk Assessment, Air Terminations, Down Conductors, and Surge Protection.

Module 8 • Formative Assessment

Instructor

PAMCET Learning Team

PAMCET Learning Team

Institutional Course Curation · PAMCET

The PAMCET Learning Team is the institutional curriculum and content group behind course publishing on this platform. PAMCET (Professional and Academic Management Centre for Education and Training) is operated by Digitpen Hub Ltd, a company registered in Lagos, Nigeria. Courses credited to the PAMCET Learning Team are structured, organized, and published centrally by the platform rather than authored by a single named individual instructor — each course's syllabus, learning outcomes, and content are reviewed before publication under this institutional account. For questions about a specific course or to report a content issue, please use the platform's Help & Support or Contact Us pages.

Qualifications:

PAMCET Learning Team — Institutional Course Curation, Digitpen Hub Ltd

My Skills:

  • Curriculum Curation
  • Course Content Review
  • Learning Outcome Design
  • Course Publishing & Quality Assurance
  • Platform Content Operations

Reviews

No reviews available
EEE 413: Electrical Building Services Design & Installation Drafting
Free$24.99100% Off
Certificate available separately for $7 after completion

Course Includes

8 Chapters
16 Lectures
2 - 4 weeks
Skill Level advanced
Taught in English
Lifetime Access
Certification of Completion
Category: University - Electrical & Electronic Engineering
Share On

Download Syllabus & Study Guide

Receive the full lecture syllabus, reading list, and milestone schedule for EEE 413: Electrical Building Services Design & Installation Drafting.

By submitting, you agree to receive educational updates. You can unsubscribe anytime. Read our Privacy Policy.