Skip to main content
B.Eng DegreeFaculty of Faculty of Engineering & TechnologyElectrical & Electronic Engineering

EEE 502: Smart Grids, Power Quality & Distributed Energy Resources

Smart grid architectures, Advanced Metering Infrastructure (AMI), power quality phenomena (harmonics, sags, swells, flicker), active power filters, and IEEE 519.

Instructor
Created by PAMCET Learning Team
advanced2 - 4 weeksEnglish

Course Overview

Smart grid architectures, Advanced Metering Infrastructure (AMI), power quality phenomena (harmonics, sags, swells, flicker), active power filters, and IEEE 519. Curriculum Structure & Core Modules: • 1. From Conventional Grids to Smart Grids: Bidirectional Power and...

What You'll Learn

  • Explain smart grid bidirectional communication and power flows, Phasor Measurement Units (PMU), and Wide-Area Monitoring (WAMS).
  • Classify power quality disturbances (voltage sags, swells, transients, interruptions, flicker) according to IEEE 1159.
  • Quantify Total Harmonic Distortion (THD) and calculate harmonic mitigation requirements under IEEE 519 standards.
  • Design passive and shunt active power filters (APF) to compensate reactive power and eliminate harmonic currents.

Requirements

  • Pass in EEE 503 and EEE 505.

Degree Programme Curriculum Context

This course is a curriculum unit of the Bachelor of Engineering (B.Eng.) in Electrical & Electronic Engineering degree framework in Nigeria.

Earn Your Certificate

Showcase your skills with a certificate! Complete the course, submit your project, and earn your certificate. Here's a sample of what you'll receive to show off your accomplishments.

course-certificate
Lecture Board & Syllabus

Course Curriculum

Browse complete theoretical foundations, worked calculations, laboratory protocols, and board assessment questions under each topic.

Launch Course Reader →
8 Chapters
•
16 Lecture
•
24h
Subtopic 1Document LectureOpen Access~22 min read

From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 1 • Lecture 1 Chapter 1: From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-PWR-04 • IEEE-EE-PWR...

Module 1 • Subtopic 1•18,011 characters of authentic academic content
Subtopic 2Document LectureOpen Access~31 min read

From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 1 • Lecture 2 Chapter 1: From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1. Applied Engineerin...

Module 1 • Subtopic 2•25,597 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 1 Formative Assessment: From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 1: From Conventional Grids to Smart Grids: Bidirectional Power and Information Flows.

Module 1 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 2 • Lecture 1 Chapter 2: Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-PWR-04 • IEEE-EE-...

Module 2 • Subtopic 1•17,861 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 2 • Lecture 2 Chapter 2: Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1. Applied Enginee...

Module 2 • Subtopic 2•27,398 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 2 Formative Assessment: Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 2: Advanced Metering Infrastructure (AMI), Smart Meters, and Demand Response Strategies.

Module 2 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118): Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 3 • Lecture 1 Chapter 3: Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118) — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • CORE...

Module 3 • Subtopic 1•17,960 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118): Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 3 • Lecture 2 Chapter 3: Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118) — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Ma...

Module 3 • Subtopic 2•27,443 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 3 Formative Assessment: Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118)

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 3: Wide-Area Monitoring Systems (WAMS), Phasor Measurement Units (PMU), and Synchrophasor Protocols (IEEE C37.118).

Module 3 • Formative Assessment
Subtopic 1Document LectureOpen Access~21 min read

Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 4 • Lecture 1 Chapter 4: Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-PWR-04...

Module 4 • Subtopic 1•17,850 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 4 • Lecture 2 Chapter 4: Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1....

Module 4 • Subtopic 2•24,716 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 4 Formative Assessment: Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 4: Power Quality Definitions and Standards: IEEE 1159, Voltage Sags, Swells, Interruptions, and Flicker.

Module 4 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 5 • Lecture 1 Chapter 5: Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-PWR-04 • IE...

Module 5 • Subtopic 1•18,083 characters of authentic academic content
Subtopic 2Document LectureOpen Access~33 min read

Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 5 • Lecture 2 Chapter 5: Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management 1. Applied E...

Module 5 • Subtopic 2•27,821 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 5 Formative Assessment: Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 5: Harmonic Sources in Power Systems: Non-Linear Loads, Switched-Mode Supplies, and Inverters.

Module 5 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 6 • Lecture 1 Chapter 6: Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-P...

Module 6 • Subtopic 1•17,934 characters of authentic academic content
Subtopic 2Document LectureOpen Access~31 min read

Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 6 • Lecture 2 Chapter 6: Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Manageme...

Module 6 • Subtopic 2•26,093 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 6 Formative Assessment: Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 6: Harmonic Analysis: Fourier Decomposition, Total Harmonic Distortion (THD), and IEEE 519 Compliance Limits.

Module 6 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters: Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 7 • Lecture 1 Chapter 7: Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • COREN-EE-PWR-...

Module 7 • Subtopic 1•17,934 characters of authentic academic content
Subtopic 2Document LectureOpen Access~30 min read

Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters: Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 7 • Lecture 2 Chapter 7: Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Management...

Module 7 • Subtopic 2•24,796 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 7 Formative Assessment: Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 7: Harmonic Mitigation: Tuned Passive LC Filters, Detuned Capacitor Banks, and Shunt Active Power Filters.

Module 7 • Formative Assessment
Subtopic 1Document LectureOpen Access~22 min read

Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR): Theoretical Foundations, Modeling & System Architecture

EEE 502 • 500L • Electrical Engineering Chapter 8 • Lecture 1 Chapter 8: Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR) — Theoretical Foundations, Mathematical Modeling & System Architecture Curriculum Alignment: Smart Grids, Power Quality & Distributed Energy Resources • NUC-CCMAS-ENG-EEE502 • CORE...

Module 8 • Subtopic 1•18,552 characters of authentic academic content
Subtopic 2Document LectureOpen Access~32 min read

Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR): Applied Engineering Computation, Production & Verification

EEE 502 • 500L • Electrical Engineering Chapter 8 • Lecture 2 Chapter 8: Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR) — Applied Engineering Computation, Production Systems & Verification Applied Computations • Numerical Simulation Protocols • Physical Testing Benchmarks • FMEA Quality Risk Ma...

Module 8 • Subtopic 2•27,146 characters of authentic academic content
Formative Assessment10 Points • 15 Mins

EEE 502 Ch 8 Formative Assessment: Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR)

Assessment Protocol:10 Total Points•70% Passing Threshold•15 Mins Time Limit•Bloom's Taxonomy: Analyze & Evaluate

Rigorous formative engineering assessment evaluating analytical and design outcomes for Chapter 8: Custom Power Devices: Distribution Static Synchronous Compensator (DSTATCOM) and Dynamic Voltage Restorer (DVR).

Module 8 • Formative Assessment

Instructor

PAMCET Learning Team

PAMCET Learning Team

Institutional Course Curation · PAMCET

The PAMCET Learning Team is the institutional curriculum and content group behind course publishing on this platform. PAMCET (Professional and Academic Management Centre for Education and Training) is operated by Digitpen Hub Ltd, a company registered in Lagos, Nigeria. Courses credited to the PAMCET Learning Team are structured, organized, and published centrally by the platform rather than authored by a single named individual instructor — each course's syllabus, learning outcomes, and content are reviewed before publication under this institutional account. For questions about a specific course or to report a content issue, please use the platform's Help & Support or Contact Us pages.

Qualifications:

PAMCET Learning Team — Institutional Course Curation, Digitpen Hub Ltd

My Skills:

  • Curriculum Curation
  • Course Content Review
  • Learning Outcome Design
  • Course Publishing & Quality Assurance
  • Platform Content Operations

Reviews

No reviews available
EEE 502: Smart Grids, Power Quality & Distributed Energy Resources
Free$24.99100% Off
Certificate available separately for $7 after completion

Course Includes

8 Chapters
16 Lectures
2 - 4 weeks
Skill Level advanced
Taught in English
Lifetime Access
Certification of Completion
Category: University - Electrical & Electronic Engineering
Share On

Download Syllabus & Study Guide

Receive the full lecture syllabus, reading list, and milestone schedule for EEE 502: Smart Grids, Power Quality & Distributed Energy Resources.

By submitting, you agree to receive educational updates. You can unsubscribe anytime. Read our Privacy Policy.